SCB10 three-winding double split epoxy cast dry-type transformer

Photovoltaic power generation as a clean energy production at home and abroad have devel-oped rapidly,$CB10 division series three-winding...

Consult Now

Product introduction

Photovoltaic power generation as a clean energy production at home and abroad have developed rapidly,SCB10 division series three-winding double epoxy cast dry-type step-up transformer is to meet the growing photovoltaic power requirements, the production company 10kV,35kV dry-type transformers,based on the digestion and absorption of foreign advanced technology combined with domestic demand self-developed products,the product has a small size,light weight,easy installation,and other advantages.


The meaning of model

Double Split epoxy cast dry-type transformers using high-quality materials,advanced manufacturing and testing equipment is made according to strict production process.It is an electric strength,mechanical strength,heat-resistant high strength dry-type transformers.Products with high reliability,long life characteristics.Suitable for photovoltaic field.Depending on the use environment,you can configure a different level of protection.

Double Split epoxy cast dry-type transformers are designed to meet the practical application of technology and has the following features:

1.Transformer was in line with local environmental conditions,such as ambient temperature and dust protection;

2.The transformer reaches the inverter rated power;

3.The transformer equipped with a temperature sensor,this signal may be input to the inverter;

4.Transformer wiring in accordance with the system requirements;

5.Rated voltage secondary winding and the inverter output voltage is consistent;

6.The rated voltage and grid connection point of the primary winding of the power supply voltage matches the scope of the primary winding is at least within ±2×2.5% range.

7.For each inverter,the transformer of this there is a separate,isolated current of the secondary winding;

8.The short-circuit voltage transformer primary winding and a secondary winding between the UK meets the system requirements;

9.Transformer short-circuit voltage UK and split coefficient 9.The two secondary windings meets the system requirements.


Product performance standard

GB1094.1-2-power Transformer

GB1094.3.5-power Transformer

GB1094.4-power Transformer

GB1094.11-dry-type power transformer

GB/T10228-dry-type power transformers technical parameters and requirements


Transformer Order Information

1.rated capacity;

2.high voltage rated voltage,tapping range;

3.low voltage rated voltage ( match with inverter ) ;

4.low-voltage rated voltage ( inverter match);

5.Impedance voltage & split efficient;

6.the frequency;

7.shell protection grade;

8.other (special) requirements.


  • WeChat

  • Service Hotline

    +86-18751902869

  • Contact

    Linda

  • Email

    linda.elysianpower@gmail.com
    809403728@qq.com

  • Website

    www.elysian-power.com

  • Address

    No. 309, Middle Nanhai Avenue, Haian Town, Haian City

  • Copyright © 2025 Elysian Power Technology (Jiangsu) Co., Ltd.  All Right Reserved.  Su ICP Bei 2026006204

    Technical Support: SUEASY

    HOME
    ABOUT
    PRODUCTS
    CONTACT