SCB10 three-winding double split epoxy cast dry-type transformer
Photovoltaic power generation as a clean energy production at home and abroad have devel-oped rapidly,$CB10 division series three-winding...
Consult Now
PRODUCT CENTER
Photovoltaic power generation as a clean energy production at home and abroad have devel-oped rapidly,$CB10 division series three-winding...
Consult NowProduct introduction
Photovoltaic power generation as a clean energy production at home and abroad have developed rapidly,SCB10 division series three-winding double epoxy cast dry-type step-up transformer is to meet the growing photovoltaic power requirements, the production company 10kV,35kV dry-type transformers,based on the digestion and absorption of foreign advanced technology combined with domestic demand self-developed products,the product has a small size,light weight,easy installation,and other advantages.
The meaning of model
Double Split epoxy cast dry-type transformers using high-quality materials,advanced manufacturing and testing equipment is made according to strict production process.It is an electric strength,mechanical strength,heat-resistant high strength dry-type transformers.Products with high reliability,long life characteristics.Suitable for photovoltaic field.Depending on the use environment,you can configure a different level of protection.
Double Split epoxy cast dry-type transformers are designed to meet the practical application of technology and has the following features:
1.Transformer was in line with local environmental conditions,such as ambient temperature and dust protection;
2.The transformer reaches the inverter rated power;
3.The transformer equipped with a temperature sensor,this signal may be input to the inverter;
4.Transformer wiring in accordance with the system requirements;
5.Rated voltage secondary winding and the inverter output voltage is consistent;
6.The rated voltage and grid connection point of the primary winding of the power supply voltage matches the scope of the primary winding is at least within ±2×2.5% range.
7.For each inverter,the transformer of this there is a separate,isolated current of the secondary winding;
8.The short-circuit voltage transformer primary winding and a secondary winding between the UK meets the system requirements;
9.Transformer short-circuit voltage UK and split coefficient 9.The two secondary windings meets the system requirements.
Product performance standard
GB1094.1-2-power Transformer
GB1094.3.5-power Transformer
GB1094.4-power Transformer
GB1094.11-dry-type power transformer
GB/T10228-dry-type power transformers technical parameters and requirements
Transformer Order Information
1.rated capacity;
2.high voltage rated voltage,tapping range;
3.low voltage rated voltage ( match with inverter ) ;
4.low-voltage rated voltage ( inverter match);
5.Impedance voltage & split efficient;
6.the frequency;
7.shell protection grade;
8.other (special) requirements.