Combined transformer system (American box changed)

ZGS11 series combined power distribution transformers is a new device (also known as theAmerican box changed),the company ...

Consult Now

ZGS11 series combined power distribution transformers is a new device (also known as the American box changed), the company is by the introduction of foreign advanced technology and design concepts,with domestic situation,specifically for the power distribution networks design of new products.Combined transformers especially for the city power grid load center, residential center,hospital,school,airport, stations ect., reduce losses and improve the quality of power supply.


Product features

1.Small size, reasonable and compact structure;

2.Sealed fuel tank , full insulation design, safe and reliable operation;

3.High overload capacity, superior performance and resistance to sudden short-circuit;

4.Ring network and terminal power supply can be used;

5.Convenient operation and reliable power supply;

6.Energy saving, low loss, loss value is not higher than the new S9;

7.Impact performance;

8.Cable Connector No.200A loads current operational,long mechanical and electrical life life.


ZGS11 Series Technical Parameters
Rated Capacity
(kVA)
Voltage combination(kV)
(H.V.) Tapping range%
(L.V.)
(kV)
Connection
group symbol
No-load
current %
No-load
loss W
Load loses
W
Short-circuit
impedance %
306,6.3,10,10.5,110.4Dyn112.1100630/6004.0
506,6.3,10,10.5,110.4Dyn112130910/8704.0
636,6.3,10,10.5,110.4Dyn111.91501090/10404.0
806,6.3,10,10.5,110.4Dyn111.81801310/12504.0
1006,6.3,10,10.5,110.4Dyn111.62001580/15004.0
1256,6.3,10,10.5,110.4Dyn111.52401890/18004.0
1606,6.3,10,10.5,110.4Dyn111.42802310/22004.0
2006,6.3,10,10.5,110.4Dyn111.33402730/26004.0
2506,6.3,10,10.5,110.4Dyn111.24003200/30504.0
3156,6.3,10,10.5,110.4Dyn111.14803830/36504.0
4006,6.3,10,10.5,110.4Dyn1115704520/43004.0
5006,6.3,10,10.5,110.4Dyn1116805410/51504.0
6306,6.3,10,10.5,110.4Dyn110.981062004.0
8006,6.3,10,10.5,110.4Dyn110.898075004.5
10006,6.3,10,10.5,110.4Dyn110.71150103004.5
12506,6.3,10,10.5,110.4Dyn110.61360120004.5
16006,6.3,10,10.5,110.4Dyn110.51640145004.5
Note: The load loss values in the table to the left of the slash applies to Dyn11 or Yzn11 Connection Group,a slash to the right of the load loss values apply to Connection Group Yyn0.
ZGS11 Series Technical Standard
NameUnitParameter
Rated CapacitykVA30~1600
Rated voltagekV6,6.3,6.6,10,10.5,11
Tapping range-±5% / ±2×2.5%
Connection-level-Dyn11
Frequency withstand voltagekV6kV grade:25kV/1min;
10kV grade:35kV/1min
Impulse voltagekV6kV grade BIL:60kV;
10kV grade BIL:75kV
Backup fuse breaking capacitykA50
Load switchA300
Thermal current:12.5kA 2S(ring),16kA 1S(terminal)
Dynamic current:31.5kA(ring),40kA(terminal)
Ambient temperature-20℃~+40℃
Top oil temperature<85
Noise leveldB≤50
  • WeChat

  • Service Hotline

    +86-18751902869

  • Contact

    Linda

  • Email

    linda.elysianpower@gmail.com
    809403728@qq.com

  • Website

    www.elysian-power.com

  • Address

    No. 309, Middle Nanhai Avenue, Haian Town, Haian City

  • Copyright © 2025 Elysian Power Technology (Jiangsu) Co., Ltd.  All Right Reserved.  Su ICP Bei 2026006204

    Technical Support: SUEASY

    HOME
    ABOUT
    PRODUCTS
    CONTACT