MNS low voltage withdrawable switchgear
This series of low-voltage withdrawable switchgear is a modular cabinet type assembled by factory with standard modules....
Consult Now
PRODUCT CENTER
This series of low-voltage withdrawable switchgear is a modular cabinet type assembled by factory with standard modules....
Consult NowProduct introduction
This series of low-voltage withdrawable switchgear is a modular cabinet type assembled by factory with standard modules.
This series of low-voltage withdrawable switchgear is suitable for power plants, substations, petrochemicals, metallurgical rolling steel, transportation energy, light industrial textiles and other factories and mines, residential quarters, high-rise buildings and other places, as power conversion, distribution and control of the power distribution equipment of power system with AC 50-60HZ, rated working voltage AC 660V and lower.
This device complies with GB7251.1 "Low-voltage Switchgear" and JB/T9961 "Low-voltage Withdrawable Switchgear" national professional standards and meets IEC439-1 international professional standards.
Conditions of use
The ambient air temperature is not higher than +40 °C, not lower than −5 °C, and its average temperature is not higher than +35 °C within 24 h.
Atmospheric conditions: air is clean, relative humidity is not more than 50% at a maximum temperature of +40 °C, and a higher relative humidity is allowed at a lower temperature, for example, 90% at +20 °C, but it should be considered that temperature changes is possible to accidentally produce condensation.
Altitude does not exceed 2000m
This device is suitable for transport and storage at temperatures ranging from −25 °C to +55 °C, up to +70 °C in a short period of time (not exceeding 24 h), under these limiting temperature the device should not be subjected to any unrecoverable damage and should work properly under normal conditions.
If the above conditions of use cannot be met, it should be resolved by the user and the manufacturer.
When the device is used in offshore oil drilling platforms and nuclear power plants, a separate technical agreement should be signed.
| Number | Project | Unit | Parameter |
|---|---|---|---|
| 1 | Rated insulation voltage | V | 660 ( 1000 ) |
| 2 | Rated operating voltage | V | 380、660 |
| 3 | Main busbar maximum operating current | A | 5000A |
| 4 | Main busbar rated withstand current | kA/s | 100/1 |
| 5 | Main busbar rated peak withstand current | kA/s | 220/0.1 |
| 6 | Distribution bus ( vertical bus ) maximum operating current | A | 1000A |
| 7 | Distribution bus ( vertical bus ) peak current | Standard type Enhanced type | 105/0.1 kA/s 176/0.1 kA/s |
| 8 | Dimensions ( width × depth × height ) | mm | 600 ( 800, 1000 ) × 800 ( 1000 ) × 2200 |